Sandwich Panel

Walk through any industrial city in Saudi Arabia, from Jeddah’s Al-Khumrah district to Riyadh’s Second Industrial City, and you will see the same thing on warehouse after warehouse: insulated metal panels on the roof and walls. The sandwich panel has become the default envelope for warehouses, factories, cold rooms, site offices and rooftop annexes because it delivers a weatherproof skin and thermal insulation in one product, installed in days rather than weeks.

But panels differ more than they look. The core material, steel gauge, coating and thickness decide how well the building stays cool, how it behaves in a fire, how long it lasts on the coast, and what it costs. This guide draws on our experience fabricating steel structures for warehouses and industrial buildings to explain what a sandwich panel is, the main types, how to choose thickness, the real advantages and disadvantages, installation basics and the factors that drive price in the Kingdom.

What Is Meant by Sandwich Panel?

A sandwich panel is a composite building panel made of two metal skins bonded to an insulating core. The name comes from its structure: two “slices” of steel with insulation in the middle. The layers are bonded in a factory under heat and pressure so the panel works as one stiff, lightweight unit.

You will also hear the terms insulated panels, insulated metal panels, composite panels and, They all describe the same basic product.

The Three Layers

  1. External skin: galvanized, pre-painted steel, usually 0.4 to 0.7 mm thick, with 0.5 mm the most common. It faces sun, rain, dust and wind.
  2. Insulating core: the heart of the panel. It sets the thermal performance, fire behaviour and weight. Common cores are EPS, PU, PIR and rock wool.
  3. Internal skin: galvanized, pre-painted steel, often the same or slightly thinner gauge than the external skin, forming the finished interior face.

Steel quality matters as much as the core, because galvanizing and paint are the first line of defence against corrosion. Our guide to galvanized steel types, uses and cost explains coating weights and why distance from the sea changes the specification.

What Are the Different Types of Sandwich Panels?

Panels are classified in two main ways: by core material and by application.

By Core Material

EPS (Expanded Polystyrene)

The most economical and lightest option. Thermal performance is acceptable but lower than PU at the same thickness, and EPS has poor fire performance, softening at relatively low temperatures. It suits temporary buildings, simple annexes and non-hazardous storage on tight budgets.

PU (Polyurethane), Also Called PUF or PUR

The most popular core for warehouses, cold rooms and annexes. Excellent insulation means you get more thermal resistance from less thickness. Fire behaviour is better than EPS, but PU is still a combustible material.

PIR (Polyisocyanurate)

An advanced variant of PU with similar or slightly better insulation and significantly better fire behaviour, because it forms a protective char layer that slows flame spread. PIR is widely specified for factories, large logistics centres and food and pharmaceutical facilities.

Rock Wool (Mineral Wool)

The best choice for fire resistance, since the core itself is non-combustible, and it also gives excellent acoustic insulation. The trade-offs are much higher weight and lower thermal performance than PU at the same thickness. Rock wool panels are used for fire walls, generator rooms and compartment partitions.

Core Comparison Table

Core Thermal insulation Fire performance Weight Best for
EPS Acceptable Poor Very light Annexes, basic storage
PU / PUF Excellent Moderate Light Warehouses, cold rooms, offices
PIR Excellent Good Light Factories, logistics, food plants
Rock wool Good Excellent Heavy Fire walls, acoustic partitions

Which Type of Panels Are Better, PUF or EPS?

For most permanent buildings in Saudi Arabia, PUF (PU) is the better choice. It insulates far better at the same thickness, which matters for air-conditioning loads in the Saudi summer, and it performs better in fire. EPS only wins on initial price for simple, non-air-conditioned or temporary structures.

By Application

  • Roof panels: the external skin has three or five raised trapezoidal ribs to shed rainwater and stiffen the panel between purlins.
  • Wall panels: flat or lightly profiled faces, often with concealed fixings for a clean facade.
  • Cold room panels: thicker, high-density cores with tight tongue-and-groove or cam-lock joints to stop air leakage.
  • Ceiling panels: used as suspended or self-supporting ceilings in clean areas and cold rooms.

Sandwich Panel Thickness and Sizes

Common core thicknesses are 50, 75, 100 and 150 mm, with some factories offering 40 and 200 mm. Effective panel width is typically around 1,000 mm, and length is cut to order, often up to 12 m.

Application Typical thickness Suitable core
Rooms, annexes, offices 50–75 mm PU
Non-air-conditioned warehouse 50 mm PU or EPS
Air-conditioned warehouse or factory 75–100 mm PU or PIR
Cold rooms 75–100 mm PU or PIR
Freezer rooms 120–150 mm PU or PIR
Fire-rated walls 80–150 mm Rock wool

Thickness alone does not define insulation. A 50 mm PU panel can outperform a 75 mm EPS panel. Always compare the panel’s U-value from the manufacturer’s data sheet.

Reading the Data Sheet

Two figures matter. The core’s thermal conductivity (lambda) measures how well the material itself insulates; lower is better. The panel’s U-value measures heat flow through the complete panel at its thickness; lower is also better. Compare quotations on U-value, not thickness, and you will often find a thinner, lighter panel that performs as well as a thicker one while easing the load on the structure.

What Are the Uses of Sandwich Panels?

  • Warehouses and hangars: the most common use, as roof and wall cladding over a steel frame. See how cladding integrates with the frame in our steel structures, warehouses and hangars.
  • Rooms and annexes: rooftop rooms, guard houses, site offices and labour accommodation.
  • Cold rooms and freezers: restaurants, supermarkets, food plants and pharmaceutical storage.
  • Factories and workshops: where a stable internal temperature protects products and people. Our guide to manufacturing industries company in Saudi Arabia covers how building envelopes fit into plant planning.
  • Internal partitions: dividing walls inside warehouses and plants.
  • Temporary project buildings: quick to erect and dismantle.

The growth of logistics in the Kingdom has pushed demand for insulated warehouses sharply upward, a trend reflected at the Saudi Warehousing and Logistics Expo, where we exhibited.

Advantages of Sandwich Panels

  • High thermal insulation: lower air-conditioning loads and energy bills in a hot climate.
  • Fast installation: a warehouse envelope can be closed in days.
  • Light weight: reduced loads on the frame and foundations, saving steel and concrete.
  • Clean, easy-to-maintain surfaces: suitable for food and pharmaceutical areas.
  • Flexibility: buildings can be extended, modified or relocated more easily than masonry.
  • Acoustic benefit: especially with rock wool cores.

What Are the Disadvantages of Sandwich Panel Walls?

  • Combustible cores: EPS and PU burn, so the core must match the fire requirements of the occupancy.
  • Joint leaks: the panel itself is waterproof, but poorly sealed joints, screws and laps leak.
  • Impact damage: the steel skin can dent under impact or overload.
  • Cut-edge corrosion: site cuts remove protection unless treated.
  • Limited load capacity: roofs need walkways for foot traffic and support for heavy suspended loads.
  • Environment-dependent life: coastal humidity demands higher-grade coatings.

Is a Sandwich Panel Waterproof?

The steel skins are impervious, so the material is waterproof. Leaks almost always come from installation: screws without sealing washers, short end laps, roof slopes below the manufacturer’s minimum, or missing flashings and closures. A correctly detailed roof with proper slope, sealed fasteners and closure pieces will not leak, even in heavy rain.

Is a Sandwich Panel Fire Resistant?

It depends entirely on the core. Rock wool is the strongest because it does not burn, PIR performs well, PU is moderate and EPS is poor. For commercial and industrial buildings, the selection must comply with the Saudi Building Code fire provisions and Civil Defense requirements, and you should ask for a fire test certificate for the actual panel system, not just the core name.

Sandwich Panel vs Corrugated Single-Skin Sheet

Single-skin corrugated sheet (known locally as shinko) is one layer of profiled steel with no insulation.

Factor Single-skin sheet Insulated panel
Construction One profiled sheet Two skins plus core
Thermal insulation Very poor High
Rain noise Loud Low
Weight Lighter Heavier
Cost Much lower Higher
Typical use Shades, non-AC storage, temporary fencing AC warehouses, factories, rooms

A middle option is single-skin sheet with insulation rolls underneath. It costs less than factory-made panels but takes longer to install and its insulation is less consistent over time.

Sandwich Panel vs Block and Concrete

Factor Insulated panels Block and concrete
Construction time Days Weeks to months
Foundation load Light Heavy
Insulation High without extra layers Needs insulated block or added layers
Impact resistance Moderate High
Fire resistance Depends on core High
Relocatable Yes No

Panels win on speed, insulation and weight; masonry wins on robustness, fire resistance and longevity. The right choice depends on use, budget and permits.

How Are Sandwich Panels Installed?

  1. Prepare the frame: check purlin alignment and spacing against the manufacturer’s span table.
  2. Set the laying direction: start against the prevailing wind so laps do not open.
  3. Lift carefully: use suitable cranes with vacuum lifters or soft slings to avoid dents.
  4. Fix the panels: self-drilling screws with EPDM sealing washers, in the pattern specified by the manufacturer.
  5. Seal the joints: tapes and approved sealants on side and end laps.
  6. Install flashings: ridge, eaves, corners, gables and gutters.
  7. Remove protective film immediately: left in the sun, it bonds to the paint.

The frame must be fabricated accurately first. Members go through iron cutting to size and metal bending, and any misalignment in the purlins shows up as waviness in the finished roof.

How to Estimate Sandwich Panel Quantities

  1. Walls: building perimeter multiplied by height, minus large doors and openings.
  2. Roof: length multiplied by width, plus an allowance for slope and overhangs.
  3. Waste: add a small allowance for cutting and laps, much lower if panels are ordered cut to length.
  4. Accessories: flashings, gutters and fasteners are measured by length and count.

The most accurate route is to send architectural drawings to the manufacturer for a cutting list.

Performance in the Saudi Climate

  • Extreme heat: roof surfaces get very hot in summer, so light, reflective colours reduce heat gain and protect the core.
  • Dust: dust builds up and traps moisture, so regular cleaning extends coating life.
  • Coastal humidity and salt: in Jeddah, Yanbu, Dammam and Jubail, specify higher-grade galvanizing and paint and treat every cut edge.
  • High winds: fixing must follow wind calculations, especially at edges and corners where suction is highest.
  • Day-night temperature swings: cause expansion and contraction, so fasteners and washers must be good quality. Surface preparation and coatings for supporting steel are covered under metal finishing.

Sandwich Panel Rooms and Cold Rooms

A sandwich panel room is one of the fastest ways to add usable space on a roof, in a yard or on a project site. Typical builds use 50 to 75 mm PU panels for walls and roof, a light steel base frame, a door, windows and pre-planned electrical routes. Cost depends on floor area, thickness, openings, finishes and the base.

Cold rooms are a more demanding application. Panels need thicker, high-density cores, tight interlocking joints, insulated floors where temperatures drop below zero, vapour-tight sealing and dedicated cold room doors. In food and pharmaceutical plants, internal skins are often specified with hygienic coatings that resist cleaning chemicals. A well-built cold room keeps temperature stable with less compressor run time, which is where better insulation pays for itself.

Coatings and Colours

Paint is protection, not just appearance. Standard polyester coatings suit most inland sites. Higher-durability modified coatings resist UV and salt better and are recommended near the coast and in industrial zones. Food-grade interior coatings resist cleaning agents.

Light colours such as white and light grey reflect more sunlight, keeping the roof surface cooler and reducing strain on the core and the air-conditioning plant, which is why they dominate warehouse roofs in Saudi Arabia. Dark colours absorb more heat and can fade faster under strong sun.

The Modern Warehouse: Frame and Envelope Together

Insulated cladding is only as good as the structure beneath it. Purlin spacing and straightness set panel performance, and many warehouses also need overhead cranes, which change frame height and loading; our guide to overhead cranes in Saudi Arabia explains the main types. Large doors, ventilation openings and services should be framed and planned before the first sandwich panel is lifted, so the envelope is not weakened by random cut-outs later.

Is a Used Sandwich Panel Worth It?

Second-hand panels can save money on temporary projects, but inspect them carefully for dented skins, core delamination, rust at edges and old screw holes. Used stock rarely comes in the lengths you need, so expect extra cutting and edge treatment.

Sandwich Panel Price in Saudi Arabia: What Drives It?

Prices follow steel coil and chemical markets, so a fixed figure dates quickly. The main drivers are:

  • Core type: EPS is cheapest, followed by PU, then PIR and rock wool.
  • Thickness: thicker panels cost more.
  • Steel gauge and coating: 0.5 mm skins cost more than 0.4 mm, and coastal-grade coatings add cost.
  • Panel type: roof, wall or cold room.
  • Quantity and lengths: larger orders and standard lengths reduce the rate.
  • Accessories: flashings, fasteners and gutters are priced separately.
  • Installation and transport: depend on city, building height and site access.

To compare quotes fairly, ask every supplier for the same core, density, skin gauges, coating, U-value and scope.

Sandwich Panel Price Range in Saudi Arabia (November 2026)

These indicative ranges come from supplier and contractor price lists published in the Saudi market during 2026. Final prices depend on core, thickness, skin gauge, quantity and city:

Item Approximate range
50 mm EPS or PU panel (supply only) SAR 75–150 per m²
75 mm PU panel (supply only) SAR 110–190 per m²
100 mm PU or rock wool panel (supply only) SAR 130–270 per m²
Fire-rated rock wool panels SAR 130–160+ per m², depending on thickness
Thick PIR panels up to 150 mm SAR 250+ per m²
Installation labour only SAR 10–25 per m², depending on site and scope
Supply and install, 50 mm SAR 150–210 per m²
Supply and install, 100 mm SAR 235–350 per m²

Worked example: a room or annex with 100 m² of 70 mm panels at SAR 115 per m² costs about SAR 11,500 in panels, around SAR 2,000 for installation and about SAR 500 for local transport, so roughly SAR 14,000 in total.

These figures usually exclude the steel frame, doors, windows, flashings and base. Always ask whether quotes include VAT and delivery. Prices move with steel coil and insulation costs, so request updated quotes with identical specifications from several manufacturers.

Questions to Ask Before Buying Sandwich Panels

  1. What exactly is the core material and density?
  2. What are the external and internal skin thicknesses, coating type and zinc coating?
  3. What is the panel’s U-value?
  4. Is there a fire test certificate for the panel system, and what classification?
  5. What is the maximum purlin spacing for this thickness?
  6. Are accessories and fasteners included?
  7. What warranty covers paint and core bonding?
  8. Who installs, and what site conditions are required?

Maintenance and Service Life

With correct installation and routine care, insulated panels last many years. Actual life depends on steel quality, coating, environment and maintenance:

  • Inspect fasteners and washers once or twice a year and replace damaged ones.
  • Clear gutters and water traps before the rainy season.
  • Touch up scratches and rust spots before they spread.
  • Wash off dust and salt in coastal and industrial areas.
  • Check and renew sealants at laps as needed.

Our Experience With Insulated Steel Buildings

Alnafie Metal Industries fabricates the steel structures that carry insulated cladding, so we understand the link between purlin spacing, panel span and roof slope, and how frame errors show up in the envelope. Our work in sheet metal and plate works and metal rolling gives us a practical view of how steel gauge and coating affect performance. For background on the steels involved, read our guide to types of steel, or see our steel fabrication buyer guide.

Planning a warehouse or hangar? Contact our team for advice on the frame and envelope together.

Frequently Asked Questions

What is meant by sandwich panel?

A composite panel made of two steel skins bonded to an insulating core, used for roofs and walls where insulation and fast construction are needed.

What is the price of sandwich panels in Saudi Arabia?

It varies with core type, thickness, steel gauge, coating, quantity and installation scope. Request quotes with identical specifications from several manufacturers to compare fairly.

Which sandwich panel is best?

PU or PIR for high thermal insulation, rock wool for fire resistance, and EPS for simple, budget projects. The best choice depends on use, fire requirements and climate.

What are the uses of sandwich panels?

Warehouses, hangars, factories, cold rooms, site offices, rooftop rooms, partitions and temporary buildings.

How are sandwich panels installed?

They are lifted onto a prepared steel frame, fixed with self-drilling sealed screws, sealed at the laps, and finished with flashings and gutters following the manufacturer’s details.

Which type of panels are better, PUF or EPS?

PUF insulates better and performs better in fire, so it is preferred for most permanent and air-conditioned buildings. EPS is cheaper and suits simple or temporary structures.

What are the different types of sandwich panels?

By core: EPS, PU (PUF), PIR and rock wool. By application: roof, wall, cold room and ceiling panels.

What are the disadvantages of sandwich panel walls?

Combustible cores in some types, joint leaks if poorly installed, vulnerability to impact, cut-edge corrosion and the need for better coatings in coastal climates.

Leave A Comment

about

Alnafie Metal Industries

AlNafie Metal Industries is a leading private company with 33 years of experience in Saudi Arabia’s development. Specializing in steel construction and tank rehabilitation, NMI provides full steel fabrication and erection services for major EPC projects, including power, gas, petrochemical, industrial, and commercial sectors.

Steel Tower Over Building

Exploring Opportunities for the Global Expansion

blog tags
No tags to display. Try to select another taxonomy.